RF-Max Digimax 210 User Manual

Browse online or download User Manual for Thermostats RF-Max Digimax 210. PROTECTOR28 - Keene Electronics

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - PROTECTOR28

PROTECTOR28  20003/120303PROTECTOR28SECURITY AND HOME AUTOMATION SYSTEM

Page 2 - CONTENTS

CONTROLS:1. CONTROL INDICATORSComes on when the remote control sends a radiosignal when keys are pressed. When the indicatorblinks only weakly, the ba

Page 3 - 2 SAFETY PRECAUTIONS

key. (e.g. living room lamp, TV, garden lights,etc.).8. BATTERY COMPARTMENT (BACK COVER)INSTALLATION:1. PLACING THE BATTERIESIMPORTANT: When placing t

Page 4 - 3.2 IMPORTANT FEATURES

At the front of the modules, you’ll find 2 codeswitches: Unit Code (1 through 16) and HouseCode (A through O). Take care that when you areusing the mo

Page 5 - 4.1 SIGNALS AND RANGE

Controls1 Battery IndicatorWhen pressing the TEST key or when a signal istransmitted, the indicator light will blink. If it onlylights up weakly, the

Page 6 - BASE STATION

14 MARMITEK4.10 DIGIMAX 210 WIRELESSTHERMOSTAT (OPTION)The RF DigiMax 210 thermostat does not needany extra wiring and works within 30 metersrange. It

Page 7

15PROTECTOR285.PROGRAMMINGTHE SC2800 BASE STATION5.1 REGISTRATION OF RADIO SENSORSEvery sensor must be installed or registered with the base station.

Page 8 - 4.3 DS10 DOOR/WINDOW SENSORS

16 MARMITEKUp to 8 remote controls can be registered with the base station (KR21 and SH624).Every time you press a key you hear a short confirmation b

Page 9 - 4.4 MS10 MOTION SENSORS

17PROTECTOR285.4 PROGRAMMING TELEPHONE NUMBERThe Marmitek SC2800 base station has a standard telephone dialler. In case of a alarm, up to 4 telephone

Page 10 - (OPTIONAL FOR PROTECTOR28/4)

18 MARMITEKThe alarm message of the telephone dialler can be recorded and re-recorded when required. The message can be up toapprox. 12 seconds. It is

Page 11 - LM12 LAMP MODULE

19PROTECTOR285.6 DELAY TIMESARMINGWhen arming the security system by means of the remote controls KR21 or SH624 in the ARM AWAY mode, the system will

Page 12 - (OPTION)

2 MARMITEKINTRODUCTIONCongratulations! You purchased a Marmitek Security System. MarmitekSecurity Systems are quality products and are manufactured wi

Page 13

20 MARMITEK5.7 JAMMING DETECTOR ON/OFFThe Marmitek SC2800 base station is equipped with a system to detect strong external interfering signal that may

Page 14 - THERMOSTAT (OPTION)

21PROTECTOR285.8 CHANGING YOUR PERSONALIDENTIFICATION CODEThis access code, is your Personal identification code. When you have changed this code, yo

Page 15 - THE SC2800 BASE STATION

22 MARMITEK5.9 ERASING OF A REGISTERED SENSOR5.10 ERASING OF ALL SENSORSIn case it is required, you can reset the base station to the factory default

Page 16 - (LOUD/SILENT ALARM)

23PROTECTOR28INSTALL – Position for installing sensors and for changing system settings. RUN 1 – For normal alarm operation.RUN 2 – For normal alarm

Page 17

24 MARMITEK6.3 WHEN AN ALARM SITUATION OCCURS• An alarm situation can only be detected when the SC2800 base station is armed• An instantaneous or dela

Page 18

25PROTECTOR28The security system can be disarmed by means of the KR21 and SH624 remote control or by using your PIN on the keyboardof the SC2800 base

Page 19 - 5.6 DELAY TIMES

26 MARMITEKA panic alarm can be activated at any time in case of an emergency, regardless if the system is armed or disarmed.You can activate a panic

Page 20 - 5.7 JAMMING DETECTOR ON/OFF

27PROTECTOR28Your security system is equipped with a wide variety of functions to control lights, extra sirens, appliances and sunshades,throughout t

Page 21 - IDENTIFICATION CODE

6.8.2. REFERENCEADDRESS FOR HOMEAUTOMATION28 MARMITEKTo control various Home Automation modules,the reference address has to be set on theSC2800 base

Page 22 - 5.10 ERASING OF ALL SENSORS

29PROTECTOR28Function addresses based on reference address:For using this function, you need the Glass BreakSensor GB10 (optional). This sensor conta

Page 23 - 6.2 ARMING THE SYSTEM

3PROTECTOR281 GENERAL• Marmitek systems are designed for use in dry environments.• Avoid placement of system components in environments with extreme

Page 24

30 MARMITEKYour SC2800 base station is equipped with a dial-in function. You now can control your security system from every touchtone phone or mobil

Page 25 - SITUATION

31PROTECTOR28When an error occurs in one of the motion or door/window sensors (e.g. battery low), you can program the base station toreport this via

Page 26 - 6.6 PANIC ALARM

32 MARMITEKThe security system does not operate:Check that the POWER indicator on the SC2800base station is on. If not, check that the PS500power supp

Page 27 - FUNCTIONS

33PROTECTOR28N.B.: When replacing the batteries of thesensor when the system is operational, you canmake sure that the sensor maintains its uniquecod

Page 28 - AUTOMATION

34 MARMITEKDECLARATION OF CONFORMITYRegarding the certification of this product Marmitek Protector28Following technical documentation analysis and/or

Page 29 - 6.9 LIFESTYLE

35PROTECTOR28

Page 31

19375844 MARMITEK3 MARMITEK SYSTEMS3.1 COMPONENTSMARMITEK SYSTEMS CONSIST OF THE FOLLOWING PARTS:1 SC2800 SECURITY CONSOLE (BASE STATION)2 PS500 MAINS

Page 32 - 9.TROUBLE SHOOTING

5PROTECTOR284 INSTALLATION OF THE COMPONENTS4.1 SIGNALS AND RANGEYour security system is using variouscommunication techniques. For a goodunderstandi

Page 33

4.2THE SC2800BASE STATION1. PANICWhen pressed, this red button initiates animmediate alarm.2. ARM HOMEAlarm function when being at home. Only doorand

Page 34 - DECLARATION OF CONFORMITY

7PROTECTOR2813. ENTERUsed for confirmation of the system settingsduring installation.14. TIME OFFUsed to set the Lifestyle mode. When pressing thiske

Page 35 - 35PROTECTOR28

CONTROLS:1. CONTROLINDICATORWhen you pressthe button TEST, orwhen the unit istransmitting asignal to the basestation, thisindicator will come on. When

Page 36

3. CODEBy pressing this key, the sensor gets a new code (1out of 65.536).N.B.: When the sensor has been installed on thesystem already, you have, afte

Comments to this Manuals

No comments